<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>16.4 кг &#8212; SETY.KZ</title>
	<atom:link href="https://sety.kz/ves/1346-7389/feed/" rel="self" type="application/rss+xml" />
	<link>https://sety.kz</link>
	<description>Инженерное оборудование</description>
	<lastBuildDate>Thu, 10 Feb 2022 06:15:00 +0000</lastBuildDate>
	<language>ru-RU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.9.2</generator>

<image>
	<url>https://sety.kz/wp-content/uploads/2021/03/fav-sety-100x100.png</url>
	<title>16.4 кг &#8212; SETY.KZ</title>
	<link>https://sety.kz</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Вентилятор осевой ВКФ 4Д 630 с фланцами</title>
		<link>https://sety.kz/product/ventilyator-osevoj-vkf-4d-630-s-flancami/</link>
		
		<dc:creator><![CDATA[prowp]]></dc:creator>
		<pubDate>Thu, 10 Feb 2022 06:14:59 +0000</pubDate>
				<guid isPermaLink="false">https://SETY.KZ/product/ventilyator-osevoj-vkf-4d-630-s-flancami/</guid>

					<description><![CDATA[Применение Вытяжные и приточно-вытяжные системы вентиляции помещений различного назначения, где требуется высокая производительность при относительно низком сопротивлении системы.Возможно использование в]]></description>
										<content:encoded><![CDATA[<h5>Применение</h5>
<p>Вытяжные и приточно-вытяжные системы вентиляции помещений различного назначения, где требуется высокая производительность при относительно низком сопротивлении системы.<br />Возможно использование в холодильной технике для охлаждения компрессорно-конденсаторных блоков.</br></p>
<h5>Конструкция</h5>
<p>Корпус и крыльчатка изготовлены из стали с полимерным покрытием. <br />Вентилятор серии ВКФ имеет наружную клеммную коробку на корпусе вентилятора.</br></p>
<h5>Мотор</h5>
<p>Двух-, четырех- или шестиполюсные асинхронные однофазные или трехфазные моторы с внешним ротором.<br />Встроенная тепловая защита с автоматическим перезапуском. Подшипники качения обеспечивают длительный срок эксплуатации до 40 000 часов.<br />Класс защиты мотора IP Х4.</br></br></p>
<h5>Регулировка скорости</h5>
<p>Ступенчатая регулировка скорости при помощи автотрансформаторного регулятора скорости и плавная регулировка скорости при помощи тиристорного регулятора скорости.<br />К одному регулятору скорости могут подключаться несколько вентиляторов, при условии, что их общая мощность и рабочий ток не будут превышать номинальные параметры регулятора скорости.</br></p>
<h5>Монтаж</h5>
<p>Вентилятор серии ВКФ устанавливается в канал при помощи соединительных фланцев.<br />Подключение к электросети осуществляется через выносную клеммную коробку.<br />Электрическое подключение и установка должны выполняться согласно инструкции и электрической схеме, указанной на клеммной коробке.</br></br></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Пластинчатый рекуператор Ровен RVP 40-20</title>
		<link>https://sety.kz/product/plastinchatyj-rekuperator-roven-rvp-40-20/</link>
		
		<dc:creator><![CDATA[prowp]]></dc:creator>
		<pubDate>Thu, 10 Feb 2022 04:13:47 +0000</pubDate>
				<guid isPermaLink="false">https://SETY.KZ/product/plastinchatyj-rekuperator-roven-rvp-40-20/</guid>

					<description><![CDATA[Пластинчатые рекуператоры служат для утилизации тепла (холода) в системах вентиляции и кондиционирования воздуха в общественных и жилых зданиях. Поверхность теплообмена]]></description>
										<content:encoded><![CDATA[<p>Пластинчатые рекуператоры служат для утилизации тепла (холода) в системах вентиляции и кондиционирования воздуха в общественных и жилых зданиях. </p>
<p>Поверхность теплообмена пластинчатых рекуператоров представляет собой наборку специально спрофилированных алюминиевых пластин толщиной 0,2 мм.</p>
<p>Корпус пластинчатых рекуператоров изготавливается из оцинкованного стального листа и оснащается специальными фланцами для установки их в системах вентиляции и кондиционирования воздуха. В холодный период года на пластинах рекуператора может образовываться некоторое количество конденсата, которое отводится через специальные штуцера и гидрозатворы.</p>
<p>Съемная крышка рекуператора конструктивно имеет наиболее низкую точку, предусмотренную для выпуска конденсата. Прилагающийся в комплекте штуцер для слива конденсата необходимо разместить в данной точке (после монтажа рекуператора), просверлив отверстие под его установку.</p>
<p><strong>Габаритные и присоединительные размеры рекуператоров:</strong></p>
</p>
<table>
<tbody>
<tr>
<td>Модель</td>
<td>Размеры, мм</td>
<td>Масса, кг</td>
</tr>
<tr>
<td>L</td>
<td>H</td>
<td>L1</td>
<td>H1</td>
<td>L2</td>
<td>H2</td>
<td>L3</td>
<td>ØD</td>
</tr>
<tr>
<td>RVP 40-20</td>
<td>400</td>
<td>200</td>
<td>420</td>
<td>220</td>
<td>516</td>
<td>260</td>
<td>474</td>
<td>9</td>
<td>16,4</td>
</tr>
<tr>
<td>RVP 50-25</td>
<td>500</td>
<td>250</td>
<td>520</td>
<td>270</td>
<td>616</td>
<td>360</td>
<td>574</td>
<td>25,4</td>
</tr>
<tr>
<td>RVP 50-30</td>
<td>500</td>
<td>300</td>
<td>520</td>
<td>320</td>
<td>616</td>
<td>360</td>
<td>574</td>
<td>25,5</td>
</tr>
<tr>
<td>RVP 60-30</td>
<td>600</td>
<td>300</td>
<td>620</td>
<td>320</td>
<td>716</td>
<td>360</td>
<td>674</td>
<td>29,4</td>
</tr>
<tr>
<td>RVP 60-35</td>
<td>600</td>
<td>350</td>
<td>620</td>
<td>420</td>
<td>716</td>
<td>410</td>
<td>674</td>
<td>31,4</td>
</tr>
<tr>
<td>RVP 70-40</td>
<td>700</td>
<td>400</td>
<td>720</td>
<td>520</td>
<td>816</td>
<td>460</td>
<td>774</td>
<td>39,6</td>
</tr>
<tr>
<td>RVP 80-50</td>
<td>800</td>
<td>500</td>
<td>820</td>
<td>530</td>
<td>916</td>
<td>560</td>
<td>874</td>
<td>51,8</td>
</tr>
<tr>
<td>RVP 90-50</td>
<td>900</td>
<td>500</td>
<td>930</td>
<td>530</td>
<td>1016</td>
<td>560</td>
<td>974</td>
<td>11</td>
<td>64,4</td>
</tr>
<tr>
<td>RVP 100-50</td>
<td>1000</td>
<td>500</td>
<td>1030</td>
<td>530</td>
<td>1116</td>
<td>570</td>
<td>1074</td>
<td>71,8</td>
</tr>
</tbody>
</table>
<p>Рекуператор сконструирован для использования в вентиляционных системах как с параллельной разводкой трассы притока и вытяжки, так и с перпендикулярной или диагональной под углом 45°С, а также их комбинаций.</p>
<p><strong>Варианты размещения рекуператора в канале в соответствии с ориентировкой колен.</strong></p>
</p>
<p><strong>Подбор рекуператора</strong></p>
<p>Для каждого рекуператора указаны графики зависимости КПД и потери давления от расхода воздуха.<br />КПД рекуператора определяется соотношением:</br></p>
<p>, где</p>
<p>to1 – температура вытяжного воздуха на входе в рекуператор, °С, tр1 – температура приточного воздуха на входе в рекуператор, °С, tр2 – температура приточного воздуха на выходе из рекуператора, °С.<br />Из данного соотношения при известном к.п.д. рекуператора можно определить требуемую температуру приточного воздуха на выходе из рекуператора tр2 из соотношения:<br />tр2 = F⋅(to1 – tр1) + tр1<br />Так как к.п.д. рекуператора непосредственно зависит от относительной влажности вытяжного воздуха, а при ее увеличении растет, то на каждом графике указаны кривые для сухого (минимального) и мокрого (максимального) к.п.д.<br />Для исходных заданных величин расхода воздуха по графику определяется сухой и мокрый к.п.д. рекуператора F. Если предполагаемая относительная влажность вытяжного воздуха лежит в диапазоне между сухим и мокрым, то по графику можно определить величину к.п.д. в диапазоне между обеими крайними кривыми.<br />В уравнение tр2 = F⋅(to1 – tр1) + tр1 подставляется определенная величина к.п.д. рекуператора и предполагаемая расчетная температура воздуха, т.е. температура приточного воздуха на входе в рекуператор и температура воздуха, удаляемого из помещения.<br />Для заданного расхода воздуха по графику определяется потеря давления рекуператора, необходимая для установки баланса потерь давления оборудования и выбора подходящего вентилятора. Конденсация влаги может заметно влиять на увеличения потери давления рекуператора от 20% до 50%. Если влажность вытяжного воздуха будет колебаться в диапазоне над величиной сухого к.п.д., рекомендуется для баланса потерь давления увеличить величину, определенную по графику минимально на 30%.<br />Полученная температура воздуха tр2 используется при подборе водяного обогревателя как температура воздуха</br></br></br></br></br></br></br></p>
<p><strong>Эффективность пластинчатых рекуператоров в зависимости от скорости потока воздуха</strong></p>
<p></br></p>
<p></br></p>
<p><strong>Байпас, защита от замерзания</strong></p>
<p>При температуре наружного воздуха ниже -10°С , необходимо выбрать установку предварительного подогрева воздуха перед рекуператором, который обеспечит повышение температуры воздуха на входе в рекуператор или установку байпаса. В противном случае, существует опасность замерзания и выход из строя всей вентсистемы.</p>
<p>Байпас рекуператора осуществляется при помощи установки заслонки и обводного канала на приточной ветке с целью обеспечения защиты от замерзания или в случае полностью автоматического отключения рекуператора в системах без охлаждения. Сечение канала байпаса должно составлять 40% сечения соединительных фланцев рекуператора.</p>