<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>9.6 кг &#8212; SETY.KZ</title>
	<atom:link href="https://sety.kz/ves/1346-7587/feed/" rel="self" type="application/rss+xml" />
	<link>https://sety.kz</link>
	<description>Инженерное оборудование</description>
	<lastBuildDate>Thu, 10 Feb 2022 05:49:21 +0000</lastBuildDate>
	<language>ru-RU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.9.2</generator>

<image>
	<url>https://sety.kz/wp-content/uploads/2021/03/fav-sety-100x100.png</url>
	<title>9.6 кг &#8212; SETY.KZ</title>
	<link>https://sety.kz</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Нагреватель канальный ЭНП 400*200-9 кВт</title>
		<link>https://sety.kz/product/nagrevatel-kanalnyj-enp-400-200-9-kvt/</link>
		
		<dc:creator><![CDATA[prowp]]></dc:creator>
		<pubDate>Thu, 10 Feb 2022 05:49:15 +0000</pubDate>
				<guid isPermaLink="false">https://SETY.KZ/product/nagrevatel-kanalnyj-enp-400-200-9-kvt/</guid>

					<description><![CDATA[Описание &#8216;Нагреватель канальный ЭНП 400*200-9 кВт&#8217; Большой диапазон мощностей – от 6 до 120 кВт Нагревательные элементы из нержавеющей стали]]></description>
										<content:encoded><![CDATA[<p><strong>Описание &#8216;Нагреватель канальный ЭНП 400*200-9 кВт&#8217;</strong></p>
<ul>
<li>Большой диапазон мощностей – от 6 до 120 кВт</li>
<li>Нагревательные элементы из нержавеющей стали</li>
<li>Регулировка температуры</li>
<li>Встроенные биметаллические термовыключатели</li>
<li>Оцинкованный стальной корпус</li>
<li>Тэны повышенной надежности</li>
<li>Степень защиты IP21</li>
<li>Максимальная температура выходного воздуха 40°C</li>
<li>Температура эксплуатации -40&#8230;+40 °С</li>
<li>Напряжение ~380 В</li>
</ul>
<p><strong>ГАБАРИТНЫЕ И ПРИСОЕДИНИТЕЛЬНЫЕ РАЗМЕРЫ (мм)</strong></p>
<table>
<tbody>
<tr>
<td>Модель</td>
<td>L</td>
<td>H</td>
<td>C</td>
<td>L1</td>
<td>H1</td>
<td>C1</td>
</tr>
<tr>
<td>ЭНП 400х200</td>
<td>400</td>
<td>200</td>
<td>500</td>
<td>545</td>
<td>202</td>
<td>430</td>
</tr>
<tr>
<td>ЭНП 500х250</td>
<td>500</td>
<td>250</td>
<td>500</td>
<td>645</td>
<td>252</td>
<td>430</td>
</tr>
<tr>
<td>ЭНП 500х300</td>
<td>500</td>
<td>300</td>
<td>500</td>
<td>645</td>
<td>302</td>
<td>430</td>
</tr>
<tr>
<td>ЭНП 600х300</td>
<td>600</td>
<td>300</td>
<td>500</td>
<td>745</td>
<td>302</td>
<td>430</td>
</tr>
<tr>
<td>ЭНП 600х350</td>
<td>600</td>
<td>350</td>
<td>500</td>
<td>745</td>
<td>352</td>
<td>430</td>
</tr>
<tr>
<td>ЭНП 700х400</td>
<td>700</td>
<td>400</td>
<td>600</td>
<td>845</td>
<td>502</td>
<td>530</td>
</tr>
<tr>
<td>ЭНП 800х500</td>
<td>800</td>
<td>500</td>
<td>600</td>
<td>945</td>
<td>502</td>
<td>530</td>
</tr>
<tr>
<td>ЭНП 1000х500</td>
<td>1000</td>
<td>500</td>
<td>600</td>
<td>1145</td>
<td>502</td>
<td>530</td>
</tr>
</tbody>
</table>
<p><strong><br /></br></strong></p>
<p><strong>СХЕМЫ ПОДКЛЮЧЕНИЯ</strong></p>
<p>Данные схемы подключения являются примером обязательного использования биметаллических термо-выключателей защиты нагревателя от перегрева t1, t2 в цепях управления силовой частью ЭНП. Категорически запрещается подключать электронагреватель без использования в его цепи управления силовой частью биметаллических термовыключателей защиты от перегрева t1, t2, в противном случае это может привести к пожару или несчастному случаю.</p>
<p><strong>Схема подключения ЭНП-1<br />Прямоугольный канальный нагреватель на 380В с одной группой ТЭНов</br></strong></p>
<table>
<tbody>
<tr>
<td></td>
<td>ЕК – нагревательный элемент,<br />t1 – биметаллический термовыключатель защиты от перегрева, 70°С,<br />t2 – биметаллический термовыключатель защиты от пожара, 130°С,<br />L1, L2, L3 – сеть</br></br></br></td>
</tr>
</tbody>
</table>
<p><strong><br /></br></strong></p>
<p><strong>Схема подключения ЭНП-2<br />Прямоугольный канальный нагреватель на 380В с двумя группами ТЭНов</br></strong></p>
<table>
<tbody>
<tr>
<td>
<p></br></p>
<p></br></p>
</td>
<td>ЕК1 – первая группа ТЭНов,<br />ЕК2 – вторая группа ТЭНов,<br />ЕК3 – третья группа ТЭНов,<br />t1 – биметаллический термовыключатель защиты от перегрева, 70С,<br />t2 – биметаллический термовыключатель защиты от пожара, 130С,<br />L1, L2, L3 – сеть</br></br></br></br></br></td>
</tr>
</tbody>
</table>
<p><strong><br /></br></strong></p>
<p><strong>Схема подключения ЭНП-3<br />Прямоугольный канальный нагреватель на 380В с тремя группами ТЭНов</br></strong></p>
<table>
<tbody>
<tr>
<td>
<p></br></p>
</td>
<td>ЕК1 – первая группа ТЭНов,<br />ЕК2 – вторая группа ТЭНов,<br />ЕК3 – третья группа ТЭНов,<br />t1 – биметаллический термовыключатель защиты от перегрева, 70С,<br />t2 – биметаллический термовыключатель защиты от пожара, 130С,<br />L1, L2, L3 – сеть</br></br></br></br></br></td>
</tr>
</tbody>
</table>
<p><strong><br /></br></strong></p>
<p><strong>Схема подключения ЭНП-4<br />Прямоугольный канальный нагреватель на 380В с четырьмя группами ТЭНов</br></strong></p>
<table>
<tbody>
<tr>
<td>
<p></br></p>
</td>
<td>ЕК1&#038;hellip,ЕК4 – группы ТЭНов,<br />t1 – биметаллический термовыключатель защиты от перегрева, 70°С,<br />t2 – биметаллический термовыключатель защиты от пожара, 130°С,<br />L1, L2, L3 – сеть</br></br></br></td>
</tr>
</tbody>
</table>
<p><strong><br /></br></strong></p>
<p><strong>Схема подключения ЭНП-5<br />Прямоугольный канальный нагреватель на 380В с пятью группами ТЭНов</br></strong></p>
<table>
<tbody>
<tr>
<td>
<p></br></p>
</td>
<td>ЕК1&#038;hellip,ЕК5 – группы ТЭНов,<br />t1 – биметаллический термовыключатель защиты от перегрева, 70°С,<br />t2 – биметаллический термовыключатель защиты от пожара, 130°С,<br />L1, L2, L3 – сеть</br></br></br></td>
</tr>
</tbody>
</table>
<p><strong><br /></br></strong></p>
<p><strong>Данные схемы подключения обязательны для цепей управления силовой частью ЭНП.<br />Категорически запрещается подключать электронагреватель без схем А1-А5</br></strong></p>
<table>
<tbody>
<tr>
<td><strong>Схема А1 для ЭНП-1</strong></td>
<td><strong>Схема А2 для ЭНП-2</strong></td>
<td><strong>Схема А3 для ЭНП-3</strong></td>
</tr>
<tr>
<td><strong></strong><strong><br /></br></strong><strong><br /></br></strong></td>
<td><strong><br /></br></strong></td>
<td></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<td><strong>Схема А4 для ЭНП-4</strong></td>
<td><strong>Схема А5 для ЭНП-5</strong></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<p>SB1, SB3, SB5, SB7, SB9 – кнопка включения,</p>
<p>SB2, SB4, SB6, SB8, SB10 – кнопка выключения магнитного пускателя КМ1,</p>
<p>KM1, KM2, КМ3, KM4, KM5 – магнитный пускатель,</p>
<p>KM1.1, KM2.1, КМ3.1, КМ4.1, КМ5.1 – н.о. дополнительный контакт магнитного пускателя.</p>
<p><strong><br /></br></strong></p>
<p><strong>ПРИМЕР ОБОЗНАЧЕНИЯ</strong></p>
<p><strong>Нагреватель электрический прямоугольный ЭНП 600х300/18</strong></p>
<p>где:</p>
<ul>
<li>ЭНП – серия канального нагревателя,</li>
<li>600х300 – типоразмер (по прямоугольному присоединительному сечению) (LxH), мм,</li>
<li>18 – мощность нагревателя, кВт.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Нагреватель канальный ЭНП 400х200-6 кВт</title>
		<link>https://sety.kz/product/nagrevatel-kanalnyj-enp-400h200-6-kvt/</link>
		
		<dc:creator><![CDATA[prowp]]></dc:creator>
		<pubDate>Thu, 10 Feb 2022 05:48:58 +0000</pubDate>
				<guid isPermaLink="false">https://SETY.KZ/product/nagrevatel-kanalnyj-enp-400h200-6-kvt/</guid>

					<description><![CDATA[Описание &#8216;Нагреватель канальный ЭНП 400*200-6 кВт&#8217; Большой диапазон мощностей – от 6 до 120 кВт Нагревательные элементы из нержавеющей стали]]></description>
										<content:encoded><![CDATA[<p><strong>Описание &#8216;Нагреватель канальный ЭНП 400*200-6 кВт&#8217;</strong></p>
<ul>
<li>Большой диапазон мощностей – от 6 до 120 кВт</li>
<li>Нагревательные элементы из нержавеющей стали</li>
<li>Регулировка температуры</li>
<li>Встроенные биметаллические термовыключатели</li>
<li>Оцинкованный стальной корпус</li>
<li>Тэны повышенной надежности</li>
<li>Степень защиты IP21</li>
<li>Максимальная температура выходного воздуха 40°C</li>
<li>Температура эксплуатации -40&#8230;+40 °С</li>
<li>Напряжение ~380 В</li>
</ul>
<p><strong>ГАБАРИТНЫЕ И ПРИСОЕДИНИТЕЛЬНЫЕ РАЗМЕРЫ (мм)</strong></p>
<table>
<tbody>
<tr>
<td>Модель</td>
<td>L</td>
<td>H</td>
<td>C</td>
<td>L1</td>
<td>H1</td>
<td>C1</td>
</tr>
<tr>
<td>ЭНП 400х200</td>
<td>400</td>
<td>200</td>
<td>500</td>
<td>545</td>
<td>202</td>
<td>430</td>
</tr>
<tr>
<td>ЭНП 500х250</td>
<td>500</td>
<td>250</td>
<td>500</td>
<td>645</td>
<td>252</td>
<td>430</td>
</tr>
<tr>
<td>ЭНП 500х300</td>
<td>500</td>
<td>300</td>
<td>500</td>
<td>645</td>
<td>302</td>
<td>430</td>
</tr>
<tr>
<td>ЭНП 600х300</td>
<td>600</td>
<td>300</td>
<td>500</td>
<td>745</td>
<td>302</td>
<td>430</td>
</tr>
<tr>
<td>ЭНП 600х350</td>
<td>600</td>
<td>350</td>
<td>500</td>
<td>745</td>
<td>352</td>
<td>430</td>
</tr>
<tr>
<td>ЭНП 700х400</td>
<td>700</td>
<td>400</td>
<td>600</td>
<td>845</td>
<td>502</td>
<td>530</td>
</tr>
<tr>
<td>ЭНП 800х500</td>
<td>800</td>
<td>500</td>
<td>600</td>
<td>945</td>
<td>502</td>
<td>530</td>
</tr>
<tr>
<td>ЭНП 1000х500</td>
<td>1000</td>
<td>500</td>
<td>600</td>
<td>1145</td>
<td>502</td>
<td>530</td>
</tr>
</tbody>
</table>
<p><strong><br /></br></strong></p>
<p><strong>СХЕМЫ ПОДКЛЮЧЕНИЯ</strong></p>
<p>Данные схемы подключения являются примером обязательного использования биметаллических термо-выключателей защиты нагревателя от перегрева t1, t2 в цепях управления силовой частью ЭНП. Категорически запрещается подключать электронагреватель без использования в его цепи управления силовой частью биметаллических термовыключателей защиты от перегрева t1, t2, в противном случае это может привести к пожару или несчастному случаю.</p>
<p><strong>Схема подключения ЭНП-1<br />Прямоугольный канальный нагреватель на 380В с одной группой ТЭНов</br></strong></p>
<table>
<tbody>
<tr>
<td></td>
<td>ЕК – нагревательный элемент,<br />t1 – биметаллический термовыключатель защиты от перегрева, 70°С,<br />t2 – биметаллический термовыключатель защиты от пожара, 130°С,<br />L1, L2, L3 – сеть</br></br></br></td>
</tr>
</tbody>
</table>
<p><strong><br /></br></strong></p>
<p><strong>Схема подключения ЭНП-2<br />Прямоугольный канальный нагреватель на 380В с двумя группами ТЭНов</br></strong></p>
<table>
<tbody>
<tr>
<td>
<p></br></p>
<p></br></p>
</td>
<td>ЕК1 – первая группа ТЭНов,<br />ЕК2 – вторая группа ТЭНов,<br />ЕК3 – третья группа ТЭНов,<br />t1 – биметаллический термовыключатель защиты от перегрева, 70С,<br />t2 – биметаллический термовыключатель защиты от пожара, 130С,<br />L1, L2, L3 – сеть</br></br></br></br></br></td>
</tr>
</tbody>
</table>
<p><strong><br /></br></strong></p>
<p><strong>Схема подключения ЭНП-3<br />Прямоугольный канальный нагреватель на 380В с тремя группами ТЭНов</br></strong></p>
<table>
<tbody>
<tr>
<td>
<p></br></p>
</td>
<td>ЕК1 – первая группа ТЭНов,<br />ЕК2 – вторая группа ТЭНов,<br />ЕК3 – третья группа ТЭНов,<br />t1 – биметаллический термовыключатель защиты от перегрева, 70С,<br />t2 – биметаллический термовыключатель защиты от пожара, 130С,<br />L1, L2, L3 – сеть</br></br></br></br></br></td>
</tr>
</tbody>
</table>
<p><strong><br /></br></strong></p>
<p><strong>Схема подключения ЭНП-4<br />Прямоугольный канальный нагреватель на 380В с четырьмя группами ТЭНов</br></strong></p>
<table>
<tbody>
<tr>
<td>
<p></br></p>
</td>
<td>ЕК1&#038;hellip,ЕК4 – группы ТЭНов,<br />t1 – биметаллический термовыключатель защиты от перегрева, 70°С,<br />t2 – биметаллический термовыключатель защиты от пожара, 130°С,<br />L1, L2, L3 – сеть</br></br></br></td>
</tr>
</tbody>
</table>
<p><strong><br /></br></strong></p>
<p><strong>Схема подключения ЭНП-5<br />Прямоугольный канальный нагреватель на 380В с пятью группами ТЭНов</br></strong></p>
<table>
<tbody>
<tr>
<td>
<p></br></p>
</td>
<td>ЕК1&#038;hellip,ЕК5 – группы ТЭНов,<br />t1 – биметаллический термовыключатель защиты от перегрева, 70°С,<br />t2 – биметаллический термовыключатель защиты от пожара, 130°С,<br />L1, L2, L3 – сеть</br></br></br></td>
</tr>
</tbody>
</table>
<p><strong><br /></br></strong></p>
<p><strong>Данные схемы подключения обязательны для цепей управления силовой частью ЭНП.<br />Категорически запрещается подключать электронагреватель без схем А1-А5</br></strong></p>
<table>
<tbody>
<tr>
<td><strong>Схема А1 для ЭНП-1</strong></td>
<td><strong>Схема А2 для ЭНП-2</strong></td>
<td><strong>Схема А3 для ЭНП-3</strong></td>
</tr>
<tr>
<td><strong></strong><strong><br /></br></strong><strong><br /></br></strong></td>
<td><strong><br /></br></strong></td>
<td></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<td><strong>Схема А4 для ЭНП-4</strong></td>
<td><strong>Схема А5 для ЭНП-5</strong></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<p>SB1, SB3, SB5, SB7, SB9 – кнопка включения,</p>
<p>SB2, SB4, SB6, SB8, SB10 – кнопка выключения магнитного пускателя КМ1,</p>
<p>KM1, KM2, КМ3, KM4, KM5 – магнитный пускатель,</p>
<p>KM1.1, KM2.1, КМ3.1, КМ4.1, КМ5.1 – н.о. дополнительный контакт магнитного пускателя.</p>
<p><strong><br /></br></strong></p>
<p><strong>ПРИМЕР ОБОЗНАЧЕНИЯ</strong></p>
<p><strong>Нагреватель электрический прямоугольный ЭНП 600х300/18</strong></p>
<p>где:</p>
<ul>
<li>ЭНП – серия канального нагревателя,</li>
<li>600х300 – типоразмер (по прямоугольному присоединительному сечению) (LxH), мм,</li>
<li>18 – мощность нагревателя, кВт.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Вентиляционный воздушный клапан РРВ 900х500</title>
		<link>https://sety.kz/product/ventilyacionnyj-vozdushnyj-klapan-rrv-900h500/</link>
		
		<dc:creator><![CDATA[prowp]]></dc:creator>
		<pubDate>Thu, 10 Feb 2022 04:29:18 +0000</pubDate>
				<guid isPermaLink="false">https://SETY.KZ/product/ventilyacionnyj-vozdushnyj-klapan-rrv-900h500/</guid>

					<description><![CDATA[Применение Регулятор расхода воздуха представляет собой многостворчатый клапан со встречным вращением пластин и предназначен для регулирования расхода воздуха или автоматического]]></description>
										<content:encoded><![CDATA[<h5>Применение</h5>
<p>Регулятор расхода воздуха представляет собой многостворчатый клапан со встречным вращением пластин и предназначен для регулирования расхода воздуха или автоматического перекрытия вентиляционного канала прямоугольного сечения.<br />Совместим с воздуховодами номинальным сечением 400х200, 500х250, 500х300, 600х300, 600х350, 700х400, 800х500, 900х500 и 1000х500 мм.</br></p>
<h5>Конструкция</h5>
<p>Корпус изготовлен из оцинкованной стали. Поворотные пластины из алюминиевого профиля вращаются при помощи пластмассовых шестеренок. Регулятор снабжен рычагом с металлической рукояткой и стопором для фиксации положения.<br />Регулятор может быть оборудован электроприводом (приобретается отдельно), при этом необходимо демонтировать рычаг с металлической рукояткой. Для установки электропривода предусмотрена специальная площадка и шток. Модели подходящих приводов приведены в таблице (см. ниже).</br></p>
<h5>Монтаж</h5>
<p>Регулятор расхода воздуха предназначен для горизонтального монтажа с прямоугольными воздуховодами и закрепления при помощи фланцевого соединения. Торцевые фланцы регулятора воздуха крепятся к ответным фланцам воздуховодов или других агрегатов вентиляционной системы.<br />Крепление осуществляется при помощи оцинкованных болтов и скоб.</br></p>
<h5>Таблица совместимости заслонок с электроприводами Belimo:</h5>
<table>
<tbody>
<tr>
<td><strong>Изделие</strong></td>
<td><strong>Тип привода</strong></td>
</tr>
<tr>
<td><strong>Электропривод, </strong><br /><strong>230 В</strong></br></td>
<td><strong>Электропривод </strong><br /><strong>с возвратной </strong><br /><strong>пружиной, 230 В</strong></br></br></td>
<td><strong>Электропривод, </strong><br /><strong>24 В</strong></br></td>
<td><strong>Электропривод </strong><br /><strong>с возвратной </strong><br /><strong>пружиной, 24 В</strong></br></br></td>
</tr>
<tr>
<td>РРВ 400х200</td>
<td>CM230 / LM230A</td>
<td>TF230 / LF230</td>
<td>CM24 / LM24A</td>
<td>TF24 / LF24</td>
</tr>
<tr>
<td>РРВ 500х250</td>
</tr>
<tr>
<td>РРВ 500х300</td>
</tr>
<tr>
<td>РРВ 600х300</td>
</tr>
<tr>
<td>РРВ 600х350</td>
</tr>
<tr>
<td>РРВ 700х400</td>
<td>LM230A</td>
<td>LF230</td>
<td>LM24A</td>
<td>LF24</td>
</tr>
<tr>
<td>РРВ 800х500</td>
</tr>
<tr>
<td>РРВ 900х500</td>
</tr>
<tr>
<td>РРВ 1000х500</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
